VPT10

VPT10

Pressure Transmitter

VPT10 is a pressure transmitter with high performance capacitive sensor, designed for differential, absolute and gauge pressure measurements, as well as models for level applications: flanged, remote seal and sanitary options.

 

 

The VPT10 is available with HART® 7 and Profibus-PA communication protocols, being a robust and highly reliable solution for pressure, level and flow measurements, ensuring efficient and reliable process results with high availability.

 

 

The DTM Libraries for HART and Profibus-PA devices can be found on:
HART    Profibus-PA

 

 

Accuracy Standard Model: ± 0.075%           High Performance Model: ± 0.05%
Communication Protocol  HART® 7 and Profibus PA
Sensor Type Microprocessor capacitive sensor, digital readout and temperature and pressure compensation algorithm
Models / Measurement Ranges D1 / -7.5 to 7.5 kPa (-30 to 30 inH2O)          
D2 / -37.4 to 37.4 kPa (-150 to 150 inH2O)                                       D3 / -186.8 to 186.8 kPa (-27 to 27 psi)       
D4 / -690 to 690 kPa (-100 to 100 psi)                                             
D5 / -2068 to 2068 kPa (-300 to 300 psi)     
D6 / -6890 to 6890 kPa (-1000 to 1000 psi)                                   M1 / -7.5 to 7.5 kPa (-30 to 30 inH2O)          
M2 / -37.4 to 37.4 kPa (-150 to 150 inH2O)                                    M3 / -100 to 186.8 kPa (-14.7 to 27 psi)      
M4 / -100 to 690 kPa (-14.7 to 100 psi)                                             M5 / -100 to 2068 kPa (-14.7 to 300 psi)     
M6 / -100 to 6890 kPa (-14.7 to 1000 psi)                                         M7 / -0.1 to 20.68 MPa (-14.7 to 3000 psi)  
A2 / 0 to 37.4 (0 to 150 inH2O)                                                         A3 / 0 to 186.8 kPa (0 to 27 psi)                   
A4 / 0 to 690 kPa (0 to 100 psi)                                                         A5 / 0 to 2068 kPa (0 to 300 psi)                  
A6 / 0 to 6890 kPa (0 to 1000 psi)                                                 H2 / -37.4 to 37.4 kPa (-150 to 150 inH2O)  
H3 / -186.8 to 186.8 kPa (-27 to 27 psi)                                        H4 / -690 to 690 kPa (-100 to 100 psi)         
H5 / -2068 to 2068 kPa (-300 to 300 psi)
Static Pressure and Overpressure Limits Ranges 1 to 5: 13 MPa (1885 psi)                                                     Range 6: 15.5 MPa (2250 psi)                      
Range 7: 46.5 MPa (6740 psi)
Stability* Standard template: ± 0.2% URL (5 years)
High performance model: ± 0.2% URL (15 years)
For ±20 °C temperature changes, 0-100% relative humidity, up to 7 MPa (70 bar) line pressure, installation according to best practices and proper assembly for processes in which hydrogen atoms may be generated (hydrogen migration).
Rangeability 150:1 or 200:1 (depending on model)
Response Time 50 ms
Output Types Linear, Square Root and Table
Temperature Limits Ambient : -40 to 85 °C
Process: -40 to 100 °C
Storage: -40 to 100 °C
Humidity Limits 0 to 100% RH (Relative Humidity)
Configuration  Remote configuration through tools based on EDDL, FDT / DTM, as well as Android platform. Local configuration via magnetic key.
Write Protection For hardware and software with an indicative on-screen icon
Totalization  Volumetric and non-volatile mass flow
Certification in Classified Area Explosion-Proof and Intrinsically Safe
Degree of Protection IP67
Mounting In the field, with pipe support Ø 2”
Housing Material  Aluminum
Approximate Weight with Bracket 4 kg

Catalogo

HART Catalog | English

DOWNLOAD

Profibus Catalog | English

DOWNLOAD

HART Catálogo | Español

DOWNLOAD

Profibus Catálogo | Español

DOWNLOAD

HART Catálogo | Português

DOWNLOAD

Profibus Catálogo | Português

DOWNLOAD

Manual

HART Manual | English

DOWNLOAD

HART Manual | Español

DOWNLOAD

Profibus Manual | English

DOWNLOAD

Profibus Manual | Español

DOWNLOAD

Manual Protocolo Profibus-PA

DOWNLOAD

HART Manual | Português

DOWNLOAD

Profibus Manual | Português

DOWNLOAD

Library

Vivace Segment Checker Library

DOWNLOAD

FAQ

Profibus FAQ | Português

DOWNLOAD

Warranty Term

VIVACE PROCESS INSTRUMENTS

DOWNLOAD

Main Benefits:

 

• Basic Accuracy: ± 0.075%
• High Accuracy: ± 0.05%
• Innovative: High Performance Microprocessor Capacitive Sensor, digital reading
• Built-in Temperature and Pressure Compensation
• Range 1: -765 to 765 mmH2O up to Range 7: -1 to 210 Kgf/cm2
• HART® 7 / 4-20mA and PROFIBUS-PA
• Totalizing with Persistence
• Square Root Extraction and User Table
• 5 Digit LCD, Rotatable, Multifunctional and Easy to Use
• Advanced Diagnostics
• Supports DD, EDDL and FDT / DTM
• No Power Polarity
• Built-in Transient Protector
• Low ETP-Probable Total Error
• High Rangeability and Stability
• Local Adjustment with Magnetic Tool

SIMILAR PRODUCTS

VMV10-P

VMV10-P - Profibus PA Mutivariable Transmitter

VMV10-P is a fully digital Multivariable Pressure and Temperature Transmitter with Profibus PA communication.
View Product
VPT11

VPT11 - Pressure Transmitter - Direct Mounting

VPT11 is a pressure transmitter with high performance piezoresistive silicon sensor, designed for direct mounting in the process pipeline.
View Product

Budget request

Category:

Next step

Previous step

Next step

We have detected that there are product(s) in your cart that need calibration or additional services.
If you wish, please specify how you want to calibrate it below..

Previous step

Next step

Previous step

This website uses cookies to ensure you get the best experience. To learn more, read our Privacy Policy. To accept!