VTT10-H is a temperature transmitter for head mounting - DIN Form B-compliant that generates 4 – 20 mA current signal (HART® 7 model) or a digital signal (Profibus-PA model), according to the measurement and user configuration.
The DTM Libraries for HART and Profibus-PA devices can be found on:
HART Profibus-PA
| Accuracy | ± 0.01% Calibrated Span |
| Power Supply / Output Current | 12 to 45 Vdc, no polarity/4-20 mA according to NAMUR-NE43 |
| Communication Protocol | HART® 7 and Profibus-PA Certified HART® Modem |
| Hazardous Area Certification | Intrinsically Safe (pending) |
| Ambient Temperature Limits | - 40 to 85°C |
| Configuration | EDDL and FDT/DTM tools, as well as PALM and Android® platform. |
| Assembly | Head Mounting according to DIN 43729 Form B |
| Protection Degree | IP00 / IP66 (Installed) |
| Electrical Isolation | Galvanic 1.5 kVac |
| Housing Material | ABS Plastic |
| Dimension / Approximate Weight | Ø 45 x 23 mm / 50 g |
Main benefits: